Chemical Tank
Troubleshooting
CrossFire 4.2
Section 5-5
No Problem / PossibleCause
Solution
~:
There is a loss of water
pressure.
1.1 There is a clogged fi/ter in the
If a filter is present in the water
water supply to the pump.
supply line to the pump, remove
and discard it.
1.2 The mix tank water supply hose is
Look inside the mix tank and
missing. This will cause aeration determine if a water inlet hose is
and turbulence in the tank.
present. If the hose is missing,
order a new hose from your
HydraMaster distributor and install
it.
1.3
Foreign material is blocking the
Inspect the outlet hole leading to
outlet hole for the pump in the
the pump in the bottom of the mix
bottom of the mix tank.
tank. Remove any foreign material
blocking the hole.
1.4 Foreign material is blocking the
Remove the water supply hose
water supply hose leading to the
between the mix tank and the
pump from the mix tank. pump. Sight through the hose.
Remove any foreign material from
the hose. Reattach the hose.
1.5 The water supply hose from the
Remove the hose and clean it. If it
mix tank to the pump is kinked or is kinked, order a replacement hose
blocked. from your HydraMaster distributor.
HydraMaster Corporation
4/5/95