CrossFire 4.2
Section 5-13
No
Problem I Possible Cause
Solution
4 There is pressure on the
gauge, but no water coming
out of the wand.
4.1 The wand jet is plugged.
Inspect and clean the jet.
4.2 The quick connect on one or more
Remove and clean or replace the
of the high pressure hoses is
defective quick connect(s).
defective.
4.3 The cleaning tool has a clogged
Remove the valve stem. Clean the
valve.
valve. Replace the “O” rings and
stem if they are bad.
4.4
The high pressure quick connect
Remove and clean or replace the
on the front of the machine is
quick connect.
clogged.
4.5 The inner lining on a hose is
Remove the restriction or replace
constricted. the hose.
,,,i
,.:;
.,’,
.,
HydraMaster Corporation
1/25/96